752 research outputs found

    Thermal structure of hot non-flaring corona from Hinode/EIS

    Full text link
    In previous studies a very hot plasma component has been diagnosed in solar active regions through the images in three different narrow-band channels of SDO/AIA. This diagnostic from EUV imaging data has also been supported by the matching morphology of the emission in the hot Ca XVII line, as observed with Hinode/EIS. This evidence is debated because of unknown distribution of the emission measure along the line of sight. Here we investigate in detail the thermal distribution of one of such regions using EUV spectroscopic data. In an active region observed with SDO/AIA, Hinode/EIS and XRT, we select a subregion with a very hot plasma component and another cooler one for comparison. The average spectrum is extracted for both, and 14 intense lines are selected for analysis, that probe the 5.5 < log T < 7 temperature range uniformly. From these lines the emission measure distributions are reconstructed with the MCMC method. Results are cross-checked with comparison of the two subregions, with a different inversion method, with the morphology of the images, and with the addition of fluxes measured with from narrow and broad-band imagers. We find that, whereas the cool region has a flat and featureless distribution that drops at temperature log T >= 6.3, the distribution of the hot region shows a well-defined peak at log T = 6.6 and gradually decreasing trends on both sides, thus supporting the very hot nature of the hot component diagnosed with imagers. The other cross-checks are consistent with this result. This study provides a completion of the analysis of active region components, and the resulting scenario supports the presence of a minor very hot plasma component in the core, with temperatures log T > 6.6.Comment: 12 pages, 8 figures, accepted for publicatio

    Principal Component Analysis to correct data systematics. Case study: K2 light curves

    Get PDF
    Instrumental data are affected by systematic effects that dominate the errors and can be relevant when searching for small signals. This is the case of the K2 mission, a follow up of the Kepler mission, that, after a failure on two reaction wheels, has lost its stability properties rising strongly the systematics in the light curves and reducing its photometric precision. In this work, we have developed a general method to remove time related systematics from a set of light curves, that has been applied to K2 data. The method uses the Principal Component Analysis to retrieve the correlation between the light curves due to the systematics and to remove its effect without knowing any information other than the data itself. We have applied the method to all the K2 campaigns available at the Mikulski Archive for Space Telescopes, and we have tested the effectiveness of the procedure and its capability in preserving the astrophysical signal on a few transits and on eclipsing binaries. One product of this work is the identification of stable sources along the ecliptic plane that can be used as photometric calibrators for the upcoming Atmospheric Remote-sensing Exoplanet Large-survey mission.Comment: 20 pages, 7 figures. Accepted for publicatio

    X-Raying the Dark Side of Venus - Scatter from Venus Magnetotail?

    Full text link
    This work analyzes the X-ray, EUV and UV emission apparently coming from the Earth-facing (dark) side of Venus as observed with Hinode/XRT and SDO/AIA during a transit across the solar disk occurred in 2012. We have measured significant X-Ray, EUV and UV flux from Venus dark side. As a check we have also analyzed a Mercury transit across the solar disk, observed with Hinode/XRT in 2006. We have used the latest version of the Hinode/XRT Point Spread Function (PSF) to deconvolve Venus and Mercury X-ray images, in order to remove possible instrumental scattering. Even after deconvolution, the flux from Venus shadow remains significant while in the case of Mercury it becomes negligible. Since stray-light contamination affects the XRT Ti-poly filter data from the Venus transit in 2012, we performed the same analysis with XRT Al-mesh filter data, which is not affected by the light leak. Even the Al-mesh filter data show residual flux. We have also found significant EUV (304 A, 193 A, 335 A) and UV (1700 A) flux in Venus shadow, as measured with SDO/AIA. The EUV emission from Venus dark side is reduced when appropriate deconvolution methods are applied; the emission remains significant, however. The light curves of the average flux of the shadow in the X-ray, EUV, and UV bands appear different as Venus crosses the solar disk, but in any of them the flux is, at any time, approximately proportional to the average flux in a ring surrounding Venus, and therefore proportional to the average flux of the solar regions around Venus obscuring disk line of sight. The proportionality factor depends on the band. This phenomenon has no clear origin; we suggest it may be due to scatter occurring in the very long magnetotail of Venus.Comment: This paper has been accepted in The Astrophysical Journa

    Asymmetric Twisting of Coronal Loops

    Get PDF
    The bright solar corona entirely consists of closed magnetic loops rooted in the photosphere. Photospheric motions are important drivers of magnetic stressing, which eventually leads to energy release into heat. These motions are chaotic and obviously different from one footpoint to the other, and in fact, there is strong evidence that loops are finely stranded. One may also expect strong transient variations along the field lines, but at a glance, coronal loops ever appear more or less uniformly bright from one footpoint to the other. We aim to understand how much coronal loops can preserve their own symmetry against asymmetric boundary motions that are expected to occur at loop footpoints. We investigate this issue by time-dependent 2.5D MHD modelling of a coronal loop, including its rooting and beta-variation in the photosphere. We assume that the magnetic flux tube is stressed by footpoint rotation but also that the rotation has a different pattern from one footpoint to the other. In this way, we force strong asymmetries because we expect independent evolution along different magnetic strands. We found that until the Alfven crossing-travel time relative to the entire loop length is much lower than the twisting period, the loop's evolution depends only on the relative velocity between the boundaries, and the symmetry is efficiently preserved. We conclude that the very high Alfven velocities that characterise the coronal environment can explain why coronal loops can maintain a very high degree of symmetry even when they are subjected to asymmetric photospheric motions for a long time

    SASE FEL Storage Ring

    Full text link
    We explore the possibility of operating a SASE FEL with a Storage Ring. We use a semi-analytical model to obtain the evolution inside the undulator by taking into account the interplay on the laser dynamics due to the induced energy spread and to the radiation damping. We obtain the Renieri's limit for the stationary output power and discuss the possibility of including in our model the effect of the beam instabilities.Comment: 5 page

    Whole-body magnetic resonance imaging (WB-MRI) for cancer screening in asymptomatic subjects of the general population: review and recommendations.

    Get PDF
    BACKGROUND:The number of studies describing the use of whole-body magnetic resonance imaging (WB-MRI) for screening of malignant tumours in asymptomatic subjects is increasing. Our aim is to review the methodologies used and the results of the published studies on per patient and per lesion analysis, and to provide recommendations on the use of WB-MRI for cancer screening. MAIN BODY:We identified 12 studies, encompassing 6214 WB-MRI examinations, which provided the rates of abnormal findings and findings suspicious for cancer in asymptomatic subjects, from the general population. Eleven of 12 studies provided imaging protocols that included T1- and T2-weighted sequences, while only five included diffusion weighted imaging (DWI) of the whole body. Different categorical systems were used for the classification and the management of abnormal findings. Of 17,961 abnormal findings reported, 91% were benign, while 9% were oncologically relevant, requiring further investigations, and 0.5% of lesions were suspicious for cancer. A per-subject analysis showed that just 5% of subjects had no abnormal findings, while 95% had abnormal findings. Findings requiring further investigation were reported in 30% of all subjects, though in only 1.8% cancer was suspected. The overall rate of histologically confirmed cancer was 1.1%. CONCLUSION:WB-MRI studies of cancer screening in the asymptomatic general population are too heterogeneous to draw impactful conclusions regarding efficacy. A 5-point lesion scale based on the oncological relevance of findings appears the most appropriate for risk-based management stratification. WB-MRI examinations should be reported by experienced oncological radiologists versed on WB-MRI reading abnormalities and on onward referral pathways
    • …
    corecore